CVE-2018-11448
A vulnerability has been identified in SCALANCE M875 (All versions). The web interface on port 443/tcp could allow a stored Cross-Site…
- Published
- Updated
- Reserved
- Assigned by
- siemens
Description
A vulnerability has been identified in SCALANCE M875 (All versions). The web interface on port 443/tcp could allow a stored Cross-Site Scripting (XSS) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires that the attacker has access to the web interface of an affected device. The attacker must be authenticated as administrative user on the web interface. Afterwards, a legitimate user must access the web interface. A successful attack could allow an attacker to execute malicious code in the browser of a legitimate user. At the time of advisory publication no public exploitation of this security vulnerability was known.
Scores
| Scored by | CVSS | Score | Vector |
|---|---|---|---|
| NVDNVD · Modified | 3.0 | Medium4.8 | CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N |
- EPSS (exploitation in 30 days)
- 0.32% · top 75% of all CVEs (5 Nov 2026)
The list uses the assigner's score when there is one, then CISA's, then NVD's: Medium 4.8.
Weakness
Affected products
- affected SCALANCE M875 All versions
References (1)
- https://cert-portal.siemens.com/productcert/pdf/ssa-977428.pdf (opens in a new tab)x_refsource_CONFIRMx_transferred
Sources
The same CVE in the primary databases and aggregators, to check against.
- CVE.org record (opens in a new tab)
- CVE List JSON (GitHub) (opens in a new tab)
- NVD (opens in a new tab)
- FIRST EPSS (opens in a new tab)
- OSV.dev (opens in a new tab)
- GitHub Advisories (opens in a new tab)
- CIRCL Vulnerability-Lookup (opens in a new tab)
Badge for a README or a ticket
[](https://trackcve.app/cve/CVE-2018-11448)Record last updated .