Skip to content
CVE Tracker
  • Newest CVEsPage
  • Recently added to KEVPage
  • Rising exploitation (EPSS)Page
  • Weekly digestPage
  • StatisticsPage
  • WatchlistPage
  • API documentationPage
  • MCP serverPage
  • Data sourcesPage
  • ChangelogPage
  • AboutPage
  • How it's builtPage
Back

CVE-2019-14356

On Coldcard MK1 and MK2 devices, a side channel for the row-based OLED display was found. The power consumption of each row-based display…

Medium5.3EPSS 1.2%
Published
Updated
Reserved
Assigned by
mitre

Description

On Coldcard MK1 and MK2 devices, a side channel for the row-based OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For example, a hardware implant in the USB cable might be able to leverage this behavior to recover confidential secrets such as the PIN and BIP39 mnemonic. In other words, the side channel is relevant only if the attacker has enough control over the device's USB connection to make power-consumption measurements at a time when secret data is displayed. The side channel is not relevant in other circumstances, such as a stolen device that is not currently displaying secret data. On Coldcard MK1 and MK2 devices, a side channel for the row-based OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For example, a hardware implant in the USB cable might be able to leverage this behavior to recover confidential secrets such as the PIN and BIP39 mnemonic. In other words, the side channel is relevant only if the attacker has enough control over the device's USB connection to make power-consumption measurements at a time when secret data is displayed. The side channel is not relevant in other circumstances, such as a stolen device that is not currently displaying secret data. NOTE: At Coinkite, we’ve already mitigated it, even though we feel strongly that it is not a legitimate issue. In our opinion, it is both unproven (might not even work) and also completely impractical—even if it could be made to work perfectly

Scores

CVSS scores of CVE-2019-14356, by who scored it
Scored byCVSSScoreVector
NVDNVD · Modified3.1Medium5.3CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
EPSS (exploitation in 30 days)
1.2% · top 32% of all CVEs (6 Nov 2026)
Loading the EPSS history…

The list uses the assigner's score when there is one, then CISA's, then NVD's: Medium 5.3.

Weakness

Affected products

  • n/a

    • affected n/a

References (2)

Sources

The same CVE in the primary databases and aggregators, to check against.

Badge for a README or a ticket

CVE-2019-14356 badge
[![CVE-2019-14356](https://trackcve.app/badge/CVE-2019-14356.svg)](https://trackcve.app/cve/CVE-2019-14356)