CVE-2019-6569
The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored…
- Published
- Updated
- Reserved
- Assigned by
- siemens
Description
The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored network. An attacker could use this behavior to transmit malicious packets to systems in the mirrored network, possibly influencing their configuration and runtime behavior.
Scores
| Scored by | CVSS | Score | Vector |
|---|---|---|---|
| NVDNVD · Modified | 3.1 | Critical9.1 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H |
- EPSS (exploitation in 30 days)
- 1.3% · top 29% of all CVEs (4 Nov 2026)
The list uses the assigner's score when there is one, then CISA's, then NVD's: Critical 9.1.
Weakness
Affected products
- affected All versions < V5.2.6
- affected All versions < V5.2.6
- affected All versions < V5.2.6
Siemens · SCALANCE X204-2LD TS
- affected All versions < V5.2.6
- affected All versions < V5.2.6
- affected All versions < V5.2.6
- affected All versions < V5.2.6
- affected All versions < V5.2.6
- affected All versions < V5.2.6
- affected All versions < V5.2.6
- affected All versions < V5.2.6
- affected All versions < V5.2.6
- affected All versions < V5.2.6
Siemens · SCALANCE X302-7 EEC (230V)
- affected All versions < V4.1.3
Siemens · SCALANCE X302-7 EEC (230V, coated)
- affected All versions < V4.1.3
Siemens · SCALANCE X302-7 EEC (24V)
- affected All versions < V4.1.3
Siemens · SCALANCE X302-7 EEC (24V, coated)
- affected All versions < V4.1.3
Siemens · SCALANCE X302-7 EEC (2x 230V)
- affected All versions < V4.1.3
Siemens · SCALANCE X302-7 EEC (2x 230V, coated)
- affected All versions < V4.1.3
Siemens · SCALANCE X302-7 EEC (2x 24V)
- affected All versions < V4.1.3
Siemens · SCALANCE X302-7 EEC (2x 24V, coated)
- affected All versions < V4.1.3
- affected All versions < V4.1.3
Siemens · SCALANCE X306-1LD FE
- affected All versions < V4.1.3
Siemens · SCALANCE X307-2 EEC (230V)
- affected All versions < V4.1.3
Siemens · SCALANCE X307-2 EEC (230V, coated)
- affected All versions < V4.1.3
Siemens · SCALANCE X307-2 EEC (24V)
- affected All versions < V4.1.3
Siemens · SCALANCE X307-2 EEC (24V, coated)
- affected All versions < V4.1.3
Siemens · SCALANCE X307-2 EEC (2x 230V)
- affected All versions < V4.1.3
Siemens · SCALANCE X307-2 EEC (2x 230V, coated)
- affected All versions < V4.1.3
Siemens · SCALANCE X307-2 EEC (2x 24V)
- affected All versions < V4.1.3
Siemens · SCALANCE X307-2 EEC (2x 24V, coated)
- affected All versions < V4.1.3
- affected All versions < V4.1.3
- affected All versions < V4.1.3
- affected All versions < V4.1.3
- affected All versions < V4.1.3
- affected All versions < V4.1.3
- affected All versions < V4.1.3
- affected All versions < V4.1.3
- affected All versions < V4.1.3
- affected All versions < V4.1.3
- affected All versions < V4.1.3
- affected All versions < V4.1.3
- affected All versions < V4.1.3
- affected All versions < V4.1.3
- affected All versions < V4.1.3
Siemens · SCALANCE X308-2M PoE
- affected All versions < V4.1.3
Siemens · SCALANCE X308-2M PoE
- affected All versions < V4.1.3
- affected All versions < V4.1.3
- affected All versions < V4.1.3
- affected All versions < V4.1.3
- affected All versions < V4.1.3
- affected All versions < V4.1.3
- affected All versions < V4.1.3
- affected All versions < V4.1.3
Siemens · SCALANCE X320-1-2LD FE
- affected All versions < V4.1.3
- affected All versions < V4.1.3
Siemens · SCALANCE XB205-3 (SC)
- affected All versions < V4.1
Siemens · SCALANCE XB205-3 (SC)
- affected All versions < V4.1
Siemens · SCALANCE XB205-3 (ST/BFOC)
- affected All versions < V4.1
Siemens · SCALANCE XB205-3 (ST/BFOC)
- affected All versions < V4.1
- affected All versions < V4.1
- affected All versions < V4.1
- affected All versions < V4.1
- affected All versions < V4.1
Siemens · SCALANCE XB213-3 (SC)
- affected All versions < V4.1
Siemens · SCALANCE XB213-3 (SC)
- affected All versions < V4.1
Siemens · SCALANCE XB213-3 (ST/BFOC)
- affected All versions < V4.1
Siemens · SCALANCE XB213-3 (ST/BFOC)
- affected All versions < V4.1
- affected All versions < V4.1
- affected All versions < V4.1
- affected All versions < V4.1
- affected All versions < V4.1
Siemens · SCALANCE XC206-2 (SC)
- affected All versions < V4.1
Siemens · SCALANCE XC206-2 (ST/BFOC)
- affected All versions < V4.1
- affected All versions < V4.1
Siemens · SCALANCE XC206-2SFP EEC
- affected All versions < V4.1
Siemens · SCALANCE XC206-2SFP G
- affected All versions < V4.1
Siemens · SCALANCE XC206-2SFP G
- affected All versions < V4.1
Siemens · SCALANCE XC206-2SFP G EEC
- affected All versions < V4.1
- affected All versions < V4.1
- affected All versions < V4.1
- affected All versions < V4.1
- affected All versions < V4.1
- affected All versions < V4.1
- affected All versions < V4.1
- affected All versions < V4.1
- affected All versions < V4.1
Siemens · SCALANCE XC216-4C G (EIP Def.)
- affected All versions < V4.1
Siemens · SCALANCE XC216-4C G EEC
- affected All versions < V4.1
- affected All versions < V4.1
- affected All versions < V4.1
- affected All versions < V4.1
Siemens · SCALANCE XC224-4C G (EIP Def.)
- affected All versions < V4.1
Siemens · SCALANCE XC224-4C G EEC
- affected All versions < V4.1
- affected All versions < V5.2.6
- affected All versions < V4.1
- affected All versions < V4.1
- affected All versions < V5.2.6
- affected All versions < V4.1
Siemens · SCALANCE XF204-2BA DNA
- affected All versions < V4.1
- affected All versions < V5.2.6
- affected All versions < V5.2.6
- affected All versions < V4.1
- affected All versions < V4.1
- affected All versions < V4.1
Siemens · SCALANCE XP208PoE EEC
- affected All versions < V4.1
- affected All versions < V4.1
- affected All versions < V4.1
- affected All versions < V4.1
Siemens · SCALANCE XP216POE EEC
- affected All versions < V4.1
Siemens · SCALANCE XR324-12M (230V, ports on front)
- affected All versions < V4.1.3
Siemens · SCALANCE XR324-12M (230V, ports on front)
- affected All versions < V4.1.3
Siemens · SCALANCE XR324-12M (230V, ports on rear)
- affected All versions < V4.1.3
Siemens · SCALANCE XR324-12M (230V, ports on rear)
- affected All versions < V4.1.3
Siemens · SCALANCE XR324-12M (24V, ports on front)
- affected All versions < V4.1.3
Siemens · SCALANCE XR324-12M (24V, ports on front)
- affected All versions < V4.1.3
Siemens · SCALANCE XR324-12M (24V, ports on rear)
- affected All versions < V4.1.3
Siemens · SCALANCE XR324-12M (24V, ports on rear)
- affected All versions < V4.1.3
Siemens · SCALANCE XR324-12M TS (24V)
- affected All versions < V4.1.3
Siemens · SCALANCE XR324-12M TS (24V)
- affected All versions < V4.1.3
Siemens · SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)
- affected All versions < V4.1.3
Siemens · SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)
- affected All versions < V4.1.3
Siemens · SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)
- affected All versions < V4.1.3
Siemens · SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)
- affected All versions < V4.1.3
Siemens · SCALANCE XR324-4M EEC (24V, ports on front)
- affected All versions < V4.1.3
Siemens · SCALANCE XR324-4M EEC (24V, ports on front)
- affected All versions < V4.1.3
Siemens · SCALANCE XR324-4M EEC (24V, ports on rear)
- affected All versions < V4.1.3
Siemens · SCALANCE XR324-4M EEC (24V, ports on rear)
- affected All versions < V4.1.3
Siemens · SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)
- affected All versions < V4.1.3
Siemens · SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)
- affected All versions < V4.1.3
Siemens · SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)
- affected All versions < V4.1.3
Siemens · SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)
- affected All versions < V4.1.3
Siemens · SCALANCE XR324-4M EEC (2x 24V, ports on front)
- affected All versions < V4.1.3
Siemens · SCALANCE XR324-4M EEC (2x 24V, ports on front)
- affected All versions < V4.1.3
Siemens · SCALANCE XR324-4M EEC (2x 24V, ports on rear)
- affected All versions < V4.1.3
Siemens · SCALANCE XR324-4M EEC (2x 24V, ports on rear)
- affected All versions < V4.1.3
Siemens · SCALANCE XR324-4M PoE (230V, ports on front)
- affected All versions < V4.1.3
Siemens · SCALANCE XR324-4M PoE (230V, ports on front)
- affected All versions < V4.1.3
Siemens · SCALANCE XR324-4M PoE (230V, ports on rear)
- affected All versions < V4.1.3
Siemens · SCALANCE XR324-4M PoE (230V, ports on rear)
- affected All versions < V4.1.3
Siemens · SCALANCE XR324-4M PoE (24V, ports on front)
- affected All versions < V4.1.3
Siemens · SCALANCE XR324-4M PoE (24V, ports on front)
- affected All versions < V4.1.3
Siemens · SCALANCE XR324-4M PoE (24V, ports on rear)
- affected All versions < V4.1.3
Siemens · SCALANCE XR324-4M PoE (24V, ports on rear)
- affected All versions < V4.1.3
Siemens · SCALANCE XR324-4M PoE TS (24V, ports on front)
- affected All versions < V4.1.3
Siemens · SCALANCE XR324-4M PoE TS (24V, ports on front)
- affected All versions < V4.1.3
Siemens · SCALANCE XR324WG (24 X FE, DC 24V)
- affected All versions < V4.1
Siemens · SCALANCE XR324WG (24 x FE, AC 230V)
- affected All versions < V4.1
Siemens · SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)
- affected All versions < V4.1
Siemens · SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)
- affected All versions < V4.1
Siemens · SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)
- affected All versions < V4.1
Siemens · SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)
- affected All versions < V4.1
Siemens · SCALANCE XR328-4C WG (28xGE, AC 230V)
- affected All versions < V4.1
Siemens · SCALANCE XR328-4C WG (28xGE, DC 24V)
- affected All versions < V4.1
Siemens · SIPLUS NET SCALANCE X308-2
- affected All versions < V4.1.3
Siemens · SIPLUS NET SCALANCE XC206-2
- affected All versions < V4.1
Siemens · SIPLUS NET SCALANCE XC206-2SFP
- affected All versions < V4.1
Siemens · SIPLUS NET SCALANCE XC208
- affected All versions < V4.1
Siemens · SIPLUS NET SCALANCE XC216-4C
- affected All versions < V4.1
References (1)
- https://cert-portal.siemens.com/productcert/pdf/ssa-557804.pdf (opens in a new tab)x_refsource_MISCx_transferred
Sources
The same CVE in the primary databases and aggregators, to check against.
- CVE.org record (opens in a new tab)
- CVE List JSON (GitHub) (opens in a new tab)
- NVD (opens in a new tab)
- FIRST EPSS (opens in a new tab)
- OSV.dev (opens in a new tab)
- GitHub Advisories (opens in a new tab)
- CIRCL Vulnerability-Lookup (opens in a new tab)
Badge for a README or a ticket
[](https://trackcve.app/cve/CVE-2019-6569)Record last updated .