CVE-2022-1159

Rockwell Automation Studio 5000 Logix Designer Code Injection

High7.7EPSS 3.5%
Published
Updated
Reserved
Assigned by
icscert

Description

Rockwell Automation Studio 5000 Logix Designer (all versions) are vulnerable when an attacker who achieves administrator access on a workstation running Studio 5000 Logix Designer could inject controller code undetectable to a user.

Timeline

  1. ID reserved

    By icscert

  2. · 3 days later

    Published

  3. · 3 years later

    Record updated

Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.

Scores

CVSS scores of CVE-2022-1159, by who scored it
Scored byCVSSScoreVector
icscertCNA (assigner)3.1High7.7CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H
NVDNVD · Modified3.1High7.2CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
EPSS (exploitation in 30 days)
3.5% · top 11% of all CVEs (7 Nov 2026)
CISA SSVC
Exploitation: none · Automatable: no · Technical impact: total
Loading the EPSS history…

The list uses the assigner's score when there is one, then CISA's, then NVD's: High 7.7.

Weakness

Affected products

What to do

Workaround: Rockwell Automation recommends users of the affected hardware and software take risk mitigation steps listed below. Users are encouraged, when possible, to combine this guidance with the general security guidelines for a comprehensive defense-in-depth strategy. There is no direct mitigation for this vulnerability in the Logix Designer application. However, a detection method is available to determine if the user program residing in the controller is identical to what was downloaded. This user program verification can be done by the following: On-demand using the Logix Designer application Compare Tool v9 or later Scheduled using FactoryTalk AssetCentre v12 or later user program verification (Available Fall 2022) To leverage these detection capabilities, users are directed to upgrade to: Studio 5000 v34 software. or later Corresponding versions of Logix 5580, 5380, 5480, GuardLogix 5580 and Compact GuardLogix 5380 controller firmware. One of the following compare tools Logix Designer application Compare Tool v9 or later – installed with Studio 5000 Logix Designer FactoryTalk AssetCentre v12 or later software (Available Fall 2022) This user program comparison must be performed on an uncompromised workstation.