CVE-2022-1372

Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in dlSlog.aspx. This allows…

Critical9.8EPSS 1.2%
Published
Updated
Reserved
Assigned by
icscert

Description

Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in dlSlog.aspx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands.

Scores

CVSS scores of CVE-2022-1372, by who scored it
Scored byCVSSScoreVector
icscertCNA (assigner)3.1Critical9.8CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
NVDNVD · Modified3.1Critical9.8CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS (exploitation in 30 days)
1.2% · top 31% of all CVEs (6 Nov 2026)
CISA SSVC
Exploitation: none · Automatable: yes · Technical impact: total
Loading the EPSS history…

The list uses the assigner's score when there is one, then CISA's, then NVD's: Critical 9.8.

Weakness

Affected products

What to do

Solution: Delta Electronics has fixed the reported vulnerabilities in Version 1.08.02.004. Users should contact Delta customer service or a Delta representative for this release, as it will not be released publicly. Delta is working on a public release that will include these fixes and other features on June 30, 2022.

Workaround: Delta also suggests users: Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolate them from the business network. Use an application firewall that can detect attacks against “Path Traversal” and “SQL Injection” weakness. Never connect programming software to any network other than the network intended for that device. When remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing a VPN is only as secure as its connected devices