CVE-2022-2969
ICSA-22-307-03 Delta Industrial Automation DIALink Path traversal
- Published
- Updated
- Reserved
- Assigned by
- icscert
Description
Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname intended to identify a file or directory located underneath a restricted parent directory. However, the software does not properly neutralize special elements within the pathname, which can cause the pathname to resolve to a location outside of the restricted directory.
Scores
| Scored by | CVSS | Score | Vector |
|---|---|---|---|
| icscertCNA (assigner) | 3.1 | High8.1 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H |
| NVDNVD · Modified | 3.1 | High7.5 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N |
- EPSS (exploitation in 30 days)
- 2.5% · top 15% of all CVEs (6 Nov 2026)
- CISA SSVC
- Exploitation: none · Automatable: no · Technical impact: partial
The list uses the assigner's score when there is one, then CISA's, then NVD's: High 8.1.
Weakness
Affected products
Delta Industrial Automation · DIALink
- affected < 1.5.0.0 Beta 4
What to do
Solution: Delta Industrial Automation has created v1.5.0.0 Beta 4 to address this vulnerability. Delta Industrial Automation will not make this update an official release; users may obtain this updated version via Delta field application engineering (FAEs) or contacting Delta Industrial Automation directly.
References (1)
Sources
The same CVE in the primary databases and aggregators, to check against.
- CVE.org record (opens in a new tab)
- CVE List JSON (GitHub) (opens in a new tab)
- NVD (opens in a new tab)
- FIRST EPSS (opens in a new tab)
- OSV.dev (opens in a new tab)
- GitHub Advisories (opens in a new tab)
- CIRCL Vulnerability-Lookup (opens in a new tab)
Badge for a README or a ticket
[](https://trackcve.app/cve/CVE-2022-2969)Record last updated .