CVE-2022-3161

The APDFL.dll contains a memory corruption vulnerability while parsing specially crafted PDF files. This could allow an attacker to…

High7.8EPSS 0.43%
Published
Updated
Reserved
Assigned by
icscert

Description

The APDFL.dll contains a memory corruption vulnerability while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process.

Scores

CVSS scores of CVE-2022-3161, by who scored it
Scored byCVSSScoreVector
icscertCNA (assigner)3.1High7.8CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
NVDNVD · Modified3.1High7.8CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
EPSS (exploitation in 30 days)
0.43% · top 62% of all CVEs (6 Nov 2026)
CISA SSVC
Exploitation: none · Automatable: no · Technical impact: total
Loading the EPSS history…

The list uses the assigner's score when there is one, then CISA's, then NVD's: High 7.8.

Weakness

Affected products

What to do

Solution: Siemens released updates for the affected products and recommends updating to the latest versions: * JT2Go: Update to V14.1.0.5 or later version https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html .  * Teamcenter Visualization V13.3: Update to V13.3.0.8 or later version https://support.sw.siemens.com/ . * Teamcenter Visualization V14.0: Update to V14.0.0.4 or later version https://support.sw.siemens.com/ . * Teamcenter Visualization V14.1: Update to V14.1.0.5 or later version https://support.sw.siemens.com/ .

Workaround: Siemens identified the following specific workaround and mitigation user can apply to reduce risk: * Do not open untrusted PDF files in JT2Go and Teamcenter Visualization. As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security https://www.siemens.com/cert/operational-guidelines-industrial-security and following the recommendations in the product manuals. Siemens also provides additional information on industrial security https://www.siemens.com/industrialsecurity . For further inquiries on security vulnerabilities in Siemens products, users should contact Siemens https://www.siemens.com/cert/advisories . For more information, see the associated Siemens security advisory SSA-360681 in HTML https://cert-portal.siemens.com/productcert/html/ssa-360681.html and CSAF https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json .