CVE-2022-33174

Power Distribution Units running on Powertek firmware (multiple brands) before 3.30.30 allows remote authorization bypass in the web…

Critical9.8EPSS 14.1%
Published
Updated
Reserved
Assigned by
mitre

Description

Power Distribution Units running on Powertek firmware (multiple brands) before 3.30.30 allows remote authorization bypass in the web interface. To exploit the vulnerability, an attacker must send an HTTP packet to the data retrieval interface (/cgi/get_param.cgi) with the tmpToken cookie set to an empty string followed by a semicolon. This bypasses an active session authorization check. This can be then used to fetch the values of protected sys.passwd and sys.su.name fields that contain the username and password in cleartext.

Scores

CVSS scores of CVE-2022-33174, by who scored it
Scored byCVSSScoreVector
mitreCNA (assigner)3.1Critical9.8CVSS:3.1/AC:L/AV:N/A:H/C:H/I:H/PR:N/S:U/UI:N
NVDNVD · Modified3.1High7.5CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
EPSS (exploitation in 30 days)
14.1% · top 3.4% of all CVEs (6 Nov 2026)
Loading the EPSS history…

The list uses the assigner's score when there is one, then CISA's, then NVD's: Critical 9.8.