CVE-2023-4957

Authentication Bypass on Zebra ZTC

Medium5.4EPSS 0.30%
Published
Updated
Reserved
Assigned by
INCIBE

Description

A vulnerability of authentication bypass has been found on a Zebra Technologies ZTC ZT410-203dpi ZPL printer. This vulnerability allows an attacker that is in the same network as the printer, to change the username and password for the Web Page by sending a specially crafted POST request to the setvarsResults.cgi file. For this vulnerability to be exploitable, the printers protected mode must be disabled.

Timeline

  1. ID reserved

    By INCIBE

  2. · 27 days later

    Published

  3. · 23 months later

    Record updated

Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.

Scores

CVSS scores of CVE-2023-4957, by who scored it
Scored byCVSSScoreVector
INCIBECNA (assigner)3.1Medium5.4CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N
NVDNVD · Modified3.1Medium4.3CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N
EPSS (exploitation in 30 days)
0.30% · top 77% of all CVEs (7 Nov 2026)
CISA SSVC
Exploitation: none · Automatable: no · Technical impact: partial
Loading the EPSS history…

The list uses the assigner's score when there is one, then CISA's, then NVD's: Medium 5.4.

Weakness

Affected products

What to do

Solution: Zebra Printers running Link-OS v6.0 and later have a protected mode that protects the printer from this vulnerability. Activating this mode disables unauthorized changes and locks the current configuration until an administrator authorizes updates. By default, the secure mode is disabled as it is necessary to generate a password first. NOTE: the ZT410 industrial printer was discontinued on Oct 1st, 2020. The service and Support discontinuation dates are in September and December 2025 depending on region. Further information regarding security settings and best practices, including “Protected Mode”, can be found in the references. UPDATE: The vulnerability has been fixed by Zebra. The updated firmware version is Link-OS v7.3 which was released March 2025. The currently released version is Link-OS v7.4 which includes the fix that was released in the previous version.