Skip to content
TrackCVE
  • Newest CVEsPage
  • Recently added to KEVPage
  • Rising exploitation (EPSS)Page
  • Weekly digestPage
  • StatisticsPage
  • WatchlistPage
  • API documentationPage
  • MCP serverPage
  • Data sourcesPage
  • ChangelogPage
  • AboutPage
  • How it's builtPage
Back

CVE-2023-6068

On affected 7130 Series FPGA platforms running MOS and recent versions of the MultiAccess FPGA, application of ACL’s may result in incorrect operation of the configured ACL for a port resulting in some packets that should be denied being permitted and some

Low3.1EPSS 0.34%
Published
Updated
Reserved
Assigned by
Arista

Description

On affected 7130 Series FPGA platforms running MOS and recent versions of the MultiAccess FPGA, application of ACL’s may result in incorrect operation of the configured ACL for a port resulting in some packets that should be denied being permitted and some

Timeline

  1. ID reserved

    By Arista

  2. · 4 months later

    Published

  3. · 5 months later

    Record updated

Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.

Scores

CVSS scores of CVE-2023-6068, by who scored it
Scored byCVSSScoreVector
AristaCNA (assigner)3.1Low3.1CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:L/A:N
NVDNVD · Analyzed3.1Low3.1CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:L/A:N
EPSS (exploitation in 30 days)
0.34% · top 73% of all CVEs (7 Nov 2026)
CISA SSVC
Exploitation: none · Automatable: no · Technical impact: partial
Loading the EPSS history…

The list uses the assigner's score when there is one, then CISA's, then NVD's: Low 3.1.

Weakness

Affected products

What to do

Solution: The recommended resolution is to upgrade to a remediated software version at your earliest convenience. Arista recommends customers move to the latest version of each release that contains all the fixes listed below. CVE-2023-6068 has been fixed in the following releases: * MultiAccess FPGA 1.8.0 and later

Workaround: The workaround is to only apply one access-list to any particular port after the MultiAccess image is loaded into the FPGA. If a new access-list is to be applied to a port, the FPGA image should be reloaded after the access-list is applied. Run the following commands to reload the FPGA image, where the line in yellow represents new access control lists to be added: switch(config-app-multiaccess)#shut switch(config-app-multiaccess)#multiaccess-group 0 client 0 access-list new_acl_if_need switch(config-app-multiaccess)#no shut The previous applied access control lists will automatically apply after FPGA reload.

Exploitation: This issue was discovered internally and Arista is not aware of any malicious uses of this issue in customer networks.

References (1)

Sources

The same CVE in the primary databases and aggregators, to check against.

Badge for a README or a ticket

CVE-2023-6068 badge
[![CVE-2023-6068](https://trackcve.app/badge/CVE-2023-6068.svg)](https://trackcve.app/cve/CVE-2023-6068)

Record last updated .