CVE-2024-4622

alpitronic Hypercharger EV Charger Use of Default Credentials

High8.3EPSS 0.49%
Published
Updated
Reserved
Assigned by
icscert

Description

If misconfigured, alpitronic Hypercharger EV charging devices can expose a web interface protected by authentication. If the default credentials are not changed, an attacker can use public knowledge to access the device as an administrator.

Scores

CVSS scores of CVE-2024-4622, by who scored it
Scored byCVSSScoreVector
icscertCNA (assigner)4.0High8.3CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:H/SC:N/SI:N/SA:N
NVDNVD · Deferred4.0High8.3CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
EPSS (exploitation in 30 days)
0.49% · top 58% of all CVEs (6 Nov 2026)
CISA SSVC
Exploitation: none · Automatable: no · Technical impact: partial
Loading the EPSS history…

The list uses the assigner's score when there is one, then CISA's, then NVD's: High 8.3.

Weakness

Affected products

What to do

Workaround: alpitronic recommends users change the default credentials for all charging devices. alpitronic advises that the interface should be connected only to internal segregated and access-controlled networks and not exposed to the public internet/web. When informed of these vulnerabilities, alpitronic, in conjunction with and/or on behalf of affected clients, disabled the interface on any exposed devices and all clients were contacted directly and reminded that the interface is not intended to be visible on the public Internet and that default passwords should be changed. alpitronic are also applying mitigations to all devices in the field and to new devices in production. New devices will come with unique passwords. Devices using the default password will be automatically assigned new unique passwords, or at first access if the device has not yet been installed. Devices with the default passwords already changed will not be affected. New passwords can be obtained by scanning the QR-Code inside the charger or in DMS portal hyperdoc. Contact Hypercharger support with any questions about newly assigned passwords.

References (2)

Sources

The same CVE in the primary databases and aggregators, to check against.

Badge for a README or a ticket

CVE-2024-4622 badge
[![CVE-2024-4622](https://trackcve.app/badge/CVE-2024-4622.svg)](https://trackcve.app/cve/CVE-2024-4622)

Record last updated .