CVE-2025-60023

AutomationDirect Productivity Suite Relative Path Traversal

Medium6.3EPSS 0.51%
Published
Updated
Reserved
Assigned by
icscert

Description

A relative path traversal vulnerability was discovered in Productivity Suite software version 4.4.1.19. The vulnerability allows an unauthenticated remote attacker to interact with the ProductivityService PLC simulator and delete arbitrary directories on the target machine.

Scores

CVSS scores of CVE-2025-60023, by who scored it
Scored byCVSSScoreVector
icscertCNA (assigner)4.0Medium6.3CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:L/SA:N
icscertCNA (assigner)3.1Medium4.0CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:N/I:L/A:N
NVDNVD · Deferred4.0Medium6.3CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:L/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
EPSS (exploitation in 30 days)
0.51% · top 56% of all CVEs (7 Nov 2026)
CISA SSVC
Exploitation: none · Automatable: yes · Technical impact: partial
Loading the EPSS history…

The list uses the assigner's score when there is one, then CISA's, then NVD's: Medium 6.3.

Weakness

Affected products

What to do

Solution: AutomationDirect recommends that users do the following: * Update the Productivity Suite programming software to version 4.5.0.x or higher. * Update the firmware of Productivity PLCs to the latest version. https://www.automationdirect.com/support/software-downloads * Although automation networks and systems come equipped with built-in password protection mechanisms, this represents a fraction of the security measures needed to safeguard these systems. * It is imperative that automation control system networks integrate data protection and security measures that match, if not exceed, the robustness of conventional business computer systems. * AutomationDirect advises users of PLCs, HMI products, and SCADA systems to conduct a thorough network security analysis to ascertain the appropriate level of security necessary for their specific application.

Workaround: AutomationDirect has identified the following mitigations for instances where systems cannot be upgraded to the latest version: * Physically disconnect the PLC from any external networks, including the internet, local area networks (LANs), and other interconnected systems. * Configure network segmentation to isolate the PLC from other devices and systems within the organization. * Implement firewall rules or network access control (NAC) policies to block incoming and outgoing traffic to the PLC. * Please refer to AutomationDirect's security considerations https://support.automationdirect.com/docs/securityconsiderations.pdf  for additional information. * If you have any questions regarding this issue, please contact AutomationDirect Technical Support at 770-844-4200 or 800-633-0405 for further assistance.

References (4)

Sources

The same CVE in the primary databases and aggregators, to check against.

Badge for a README or a ticket

CVE-2025-60023 badge
[![CVE-2025-60023](https://trackcve.app/badge/CVE-2025-60023.svg)](https://trackcve.app/cve/CVE-2025-60023)

Record last updated .