Toptech Systems RCU II+ and Multiload II+ Missing Authentication for Critical Function

High8.7EPSS 0.46%
Published
Updated
Reserved
Assigned by
icscert

Description

The RCU II+ and Multiload II+ are vulnerable to an unauthenticated service that exposes a debug interface granting full root-level access to the embedded system. This vulnerability stems from a network-accessible port running a Target Communications Framework (TCF) service that does not require any authentication, allowing an attacker to directly interact with the Linux environment that powers the device. Once connected, an attacker can freely view and modify the filesystem, manipulate running processes, and control network interfaces, enabling deep alteration of system behavior.

Timeline

  1. ID reserved

    By icscert

  2. · 43 days later

    Published

  3. · 1 day later

    Record updated

Changes after publication (a new score, a public exploit, EPSS crossing 1, 10 or 50 %, leaving KEV) are kept since November 2026; earlier ones are not known.

Scores

CVSS scores of CVE-2026-12562, by who scored it
Scored byCVSSScoreVector
icscertCNA (assigner)4.0High8.7CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
icscertCNA (assigner)3.1High8.8CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
NVDNVD · Deferred4.0High8.7CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
EPSS (exploitation in 30 days)
0.46% · top 60% of all CVEs (7 Nov 2026)
CISA SSVC
Exploitation: none · Automatable: no · Technical impact: total
Loading the EPSS history…

The list uses the assigner's score when there is one, then CISA's, then NVD's: High 8.7.

Weakness

Affected products

What to do

Solution: Toptech Systems provides two methods for remediating affected RCU II+ and Multiload II+ units: First, move the device to a closed or segmented network without untrusted access. Run one of the RCU II+/Multiload II+ Vulnerability Removal Tools (VRT) available at https://s3.amazonaws.com/docs.toptech.com/nonpublic/rcuiip_mliip_vrt.zip , https://s3.amazonaws.com/docs.toptech.com/nonpublic/rcuiip_mliip_vrt.gz. * This option does not require breaking Weights and Measures seals and has the least operational impact. Install the latest firmware from https://s3.amazonaws.com/docs.toptech.com/index.html#downloads/Firmware/RCUII+_MLII+_SMPII+/ . * This method requires stopping the bay and breaking the W&M seal. Be sure to back up the current ML configuration before performing the firmware update. For questions, contact Toptech Systems Support at [email protected]. Additional details are available in Toptech System's firmware vulnerability notice: https://s3.amazonaws.com/docs.toptech.com/nonpublic/2025%2012%2001%20RCU%20IIPlus%20MultiLoad%20IIPlus%20Vulnerability%20Notice.pdf .