Honeywell IQ4x BMS Controller Missing authentication for critical function

Critical10.0EPSS 5.7%
Published
Updated
Reserved
Assigned by
icscert

Description

The Honeywell IQ4x building management controller, exposes its full web-based HMI without authentication in its factory-default configuration. With no user module configured, security is disabled by design and the system operates under a System Guest (level 100) context, granting read/write privileges to any party able to reach the HTTP interface. Authentication controls are only enforced after a web user is created via U.htm, which dynamically enables the user module. Because this function is accessible prior to authentication, a remote user can create a new account with administrative read/write permissions enabling the user module and imposing authentication under attacker-controlled credentials. This action can effectively lock legitimate operators out of local and web-based configuration and administration.

Scores

CVSS scores of CVE-2026-3611, by who scored it
Scored byCVSSScoreVector
icscertCNA (assigner)4.0Critical10.0CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
icscertCNA (assigner)3.1Critical10.0CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
NVDNVD · Analyzed4.0Critical10.0CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
EPSS (exploitation in 30 days)
5.7% · top 6.9% of all CVEs (6 Nov 2026)
CISA SSVC
Exploitation: none · Automatable: yes · Technical impact: total
Loading the EPSS history…

The list uses the assigner's score when there is one, then CISA's, then NVD's: Critical 10.0.

Weakness

Affected products

What to do

Workaround: Honeywell is aware of the issue, but has not released a fix. For more information, contact Honeywell directly. [https://www.honeywell.com/us/en/contact](https://www.honeywell.com/us/en/contact).