CVE-2026-4932

This Power System update is being released to address Insufficient Entropy

Medium4.2EPSS 0.11%
Published
Updated
Reserved
Assigned by
ibm

Description

IBM PowerVM Hypervisor FW1110.00 through FW1110.20, and FW1060.00 through FW1060.71 could allow an attacker with physical access to the Transparent Memory Encryption (TME) hardware to decrypt encrypted memory due to insufficient cryptographic entropy.

Scores

CVSS scores of CVE-2026-4932, by who scored it
Scored byCVSSScoreVector
ibmCNA (assigner)3.1Medium4.2CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N
NVDNVD · Analyzed3.1Medium4.6CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
EPSS (exploitation in 30 days)
0.11% · top 99% of all CVEs (5 Nov 2026)
CISA SSVC
Exploitation: none · Automatable: no · Technical impact: partial
Loading the EPSS history…

The list uses the assigner's score when there is one, then CISA's, then NVD's: Medium 4.2.

Weakness

Affected products

What to do

Solution: Customers with the products below should install FW1110.30(1110_125), or newer and reboot the system to remediate this vulnerability. Power 11 * IBM Power System E1180 (9080-HEU) Customers with the products below should install FW1110.30(1110_145), or newer and reboot the system to remediate this vulnerability. Power 11 * IBM Power System S1122 (9824-22A) * IBM Power System S1124 (9824-42A) * IBM Power System S1122s (9824-22B) * IBM Power System S1114 (9824-41B) * IBM Power System L1122 (9856-22H) * IBM Power System L1124 (9856-42H) * IBM Power System E1150 (9043-MRU) Customers with the products below should install FW1060.72(1060_171)/FW1060.80(1060_180), or newer and reboot the system to remediate this vulnerability. Power 10 * IBM Power System E1080 (9080-HEX) Customers with the products below should install  FW1060.72(1060_177)/FW1060.80(1060_185),  or newer and reboot the system to remediate this vulnerability. Power 10 * IBM Power System S1022 (9105-22A) * IBM Power System S1024 (9105-42A) * IBM Power System S1022s (9105-22B) * IBM Power System S1014 (9105-41B) * IBM Power System L1022 (9786-22H) * IBM Power System L1024 (9786-42H) * IBM Power System E1050 (9043-MRX) * IBM Power System S1012 (9028-21B)

Workaround: NOTE: If performing a concurrent upgrade you must reboot the system after updating to the new firmware level to generate fresh TME encryption keys and mitigate this CVE