CVE-2026-64896

T2000 open debug port

Medium5.2EPSS 0.19%
Published
Updated
Reserved
Assigned by
jci

Description

Debug and Test Interface With Improper Access Control vulnerability in Johnson Controls T2000 allows Accessing Functionality Not Properly Constrained by ACLs. This issue affects T2000: before 31.6.

Scores

CVSS scores of CVE-2026-64896, by who scored it
Scored byCVSSScoreVector
jciCNA (assigner)4.0Medium5.2CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:H/SC:N/SI:N/SA:N
NVDNVD · Awaiting Analysis4.0Medium5.2CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
EPSS (exploitation in 30 days)
0.19% · top 91% of all CVEs (7 Nov 2026)
CISA SSVC
Exploitation: none · Automatable: no · Technical impact: partial
Loading the EPSS history…

The list uses the assigner's score when there is one, then CISA's, then NVD's: Medium 5.2.

Weakness

Affected products

What to do

Workaround: If immediate update is not possible, Johnson Controls recommends the following mitigations:  * Restrict physical access to the device by installing it in a secured equipment room that limits access to authorized service personnel only.  * Implement tamper-evident seals on device housings and panel enclosures to detect and deter unauthorized physical access attempts.  * Conduct periodic physical inspections of device installations to identify signs of tampering, unauthorized cable connections, or enclosure breaches.  Additional best-practice mitigations that end users can apply as a layer of defense:  * Physically secure the device enclosure to prevent unauthorized access to internal circuit boards and ports.  * Implement authentication mechanisms on any accessible debug interfaces to restrict access to authorized service personnel only.  * Monitor physical access to device installations and implement tamper detection where possible.  * Follow the recommendations in the Johnson Controls Product Hardening Guide available at  https://www.johnsoncontrols.com/trust-center/cybersecurity/resources .  These mitigations reduce risk but may not fully remediate the vulnerability.