Vivotek vulnerabilities
12 published CVEs name Vivotek among the affected products.
- Published CVEs
- 12
- Last 12 months
- 6
- Critical
- 3
- Known exploited
- 0
Critical 3High 4Medium 5Low 0Not scored 0
CVEs per yearBy the year they were published
- 20245
- 20252
- 20265
Newest CVEs
- CVE-2026-22755
Legacy Vivotek Camera Firmware Command Injection in upload_map.cgi
Vivotek · Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB9330
Critical9.3 - CVE-2025-66052
Command injection in Vivotek IP7137 cameras
Vivotek · IP7137
High8.6 - CVE-2025-66051
Path traversal in Vivotek IP7137 cameras
Vivotek · IP7137
Medium6.9 - CVE-2025-66050
No password set for administrative account in Vivotek IP7137 cameras
Vivotek · IP7137
Critical9.3 - CVE-2025-66049
Unprotected RTSP stream in Vivotek IP7137 cameras
Vivotek · IP7137
High8.7 - CVE-2025-12592
Use of default login credentials in Legacy Vivotek Devices
Vivotek · Affected device model numbers are FD7131-VVTK,FD7131-VVTK,FD7131-VVTK,FD7141-VVTK,IP7131-VVTK,IP7133-VVTK,IP7133-VVTK,IP7133-VVTK,IP7134-VVTK,IP7135-VVTK,IP7135-VVTK,IP7135-VVTK,IP7135-VVTK,IP7137-VVTK,IP7137-VVTK,IP7137-VVTK,IP7137-VVTK,IP7137-VVTK,IP7137-VVTK,IP7138-VVTK,IP7142-VVTK,IP7142-VVTK,IP7151-VVTK,IP7152-VVTK,IP7153-VVTK,IP7153-VVTK,IP7154-VVTK,IP7330-VVTK,IP7330-VVTK,IP7330-VVTK,IP8131-VVTK,IP8131-VVTK,IP8131-VVTK,IP8131W-VVTK,PT7135-VVTK,PT7137-TCON,PT7137-VVTK,PT7137-VVTK,PT7137-VVTK,PT7137-VVTK,PZ7131-VVTK,PZ7131-VVTK,PZ71X1-VVTK,PZ71X1-VVTK,PZ71X2-VVTK,SD73X3-VVTK,SD73X3-VVTK,SD73X3-VVTK,TC5330-VVTK,TC5332-TCVV,TC5333-TCVV,TC5633-TCVV,TC5633-VVTK,VS7100-VVTK,VS7100-VVTK,VS7100-VVTK
Critical9.3 - CVE-2025-3403
Vivotek NVR ND8422P/NVR ND9525P/NVR ND9541P HTML Form sensitive information in source
Vivotek · NVR ND8422P
Medium5.1 - CVE-2024-7443
Vivotek IB8367A upload_file.cgi getenv command injection
Vivotek · IB8367A
Medium5.3 - CVE-2024-7442
Vivotek SD9364 upload_file.cgi getenv command injection
Vivotek · SD9364
Medium5.3 - CVE-2024-7441
Vivotek SD9364 httpd read stack-based overflow
Vivotek · SD9364
High8.7
Products with the most CVEs
- IP71374
- CC81602
- SD93642
- Affected device model numbers are FD7131-VVTK,FD7131-VVTK,FD7131-VVTK,FD7141-VVTK,IP7131-VVTK,IP7133-VVTK,IP7133-VVTK,IP7133-VVTK,IP7134-VVTK,IP7135-VVTK,IP7135-VVTK,IP7135-VVTK,IP7135-VVTK,IP7137-VVTK,IP7137-VVTK,IP7137-VVTK,IP7137-VVTK,IP7137-VVTK,IP7137-VVTK,IP7138-VVTK,IP7142-VVTK,IP7142-VVTK,IP7151-VVTK,IP7152-VVTK,IP7153-VVTK,IP7153-VVTK,IP7154-VVTK,IP7330-VVTK,IP7330-VVTK,IP7330-VVTK,IP8131-VVTK,IP8131-VVTK,IP8131-VVTK,IP8131W-VVTK,PT7135-VVTK,PT7137-TCON,PT7137-VVTK,PT7137-VVTK,PT7137-VVTK,PT7137-VVTK,PZ7131-VVTK,PZ7131-VVTK,PZ71X1-VVTK,PZ71X1-VVTK,PZ71X2-VVTK,SD73X3-VVTK,SD73X3-VVTK,SD73X3-VVTK,TC5330-VVTK,TC5332-TCVV,TC5333-TCVV,TC5633-TCVV,TC5633-VVTK,VS7100-VVTK,VS7100-VVTK,VS7100-VVTK1
- Affected device model numbers are FD8365, FD8365v2, FD9165, FD9171, FD9187, FD9189, FD9365, FD9371, FD9381, FD9387, FD9389, FD9391,FE9180,FE9181, FE9191, FE9381, FE9382, FE9391, FE9582, IB9365, IB93587LPR, IB9371,IB9381, IB9387, IB9389, IB939,IP9165,IP9171, IP9172, IP9181, IP9191, IT9389, MA9321, MA9322, MS9321, MS9390, TB93301
- IB8367A1
- NVR ND8422P1
- NVR ND9525P1