Every public CVE, as it is published
The whole CVE List, enriched with NVD scores, CISA's known exploited catalog and EPSS exploit probabilities. Updated every few minutes; last read 3 min ago.
At a glance
Published CVEs; rejected ones are not counted.
- 400,565All CVEsplus 18,890 rejected
- 360Last 24 hours2,992 in the last 7 days
- 17,093Last 30 days1,578 of them critical
- 1,768Known exploitedin the CISA KEV catalog
CVEs published per year
All time, by publication date in UTC; follows the filter above.
- Critical
- High
- Medium
- Low
- Not scored
Show the numbers as a table
| Period | Critical | High | Medium | Low | Not scored | Total | Cumulative |
|---|---|---|---|---|---|---|---|
| 2026 | 0 | 0 | 0 | 0 | 0 | 0 | 20 |
| 2025 | 0 | 0 | 0 | 0 | 0 | 0 | 20 |
| 2024 | 11 | 1 | 0 | 0 | 0 | 12 | 20 |
| 2023 | 0 | 0 | 0 | 0 | 0 | 0 | 8 |
| 2022 | 0 | 0 | 3 | 1 | 0 | 4 | 8 |
| 2021 | 0 | 0 | 0 | 0 | 0 | 0 | 4 |
| 2020 | 0 | 0 | 0 | 0 | 0 | 0 | 4 |
| 2019 | 3 | 0 | 1 | 0 | 0 | 4 | 4 |
| Title | ||
|---|---|---|
| CVE-2024-48967 | Life2000 ventilator and Service PC lack sufficient audit logging capabilitiesBaxter · Life2000 Ventilation System | Critical10.0 |
| CVE-2024-48966 | Life2000 service tools for test and calibration do not support user authenticationBaxter · Life2000 Ventilation System | Critical10.0 |
| CVE-2024-48970 | Life2000 Ventilator microcontroller lacks memory protectionBaxter · Life2000 Ventilation System | Critical9.3 |
| CVE-2024-48974 | Life2000 Ventilator does not perform proper file integrity checks when adopting firmware updatesBaxter · Life2000 Ventilation System | Critical9.3 |
| CVE-2024-48973 | Debug port on Life2000 Ventilator serial interface is enabled by defaultBaxter · Life2000 Ventilation System | Critical9.3 |
| CVE-2024-48971 | Clinician Password and Serial Number Clinician Password are hard-coded in Life2000 VentilatorBaxter · Life2000 Ventilation System | Critical9.3 |
| CVE-2024-9832 | No limit on failed login attempts with Clinician Password or Serial Number Clinician Password on Life2000 VentilatorBaxter · Life2000 Ventilation System | Critical9.3 |
| CVE-2024-9834 | Improper data protection on Life2000 ventilator serial interfaceBaxter · Life2000 Ventilation System | Critical9.3 |
| CVE-2024-6796 | Vulnerability in Baxter Connex Health PortalBaxter · Connex Health Portal | High8.2 |
| CVE-2024-6795 | Vulnerability in Baxter Connex Health PortalBaxter · Connex Health Portal | Critical10.0 |
| CVE-2024-5176 | Vulnerability in Welch Allyn Configuration Tool SoftwareBaxter · Welch Allyn Configuration Tool | Critical9.4 |
| CVE-2024-1275 | Vulnerability in Baxter Welch Allyn Connex Spot MonitorBaxter · Welch Allyn Connex Spot Monitor | Critical9.1 |
| CVE-2022-26393 | Format String vulnerabilityBaxter · Baxter Spectrum Wireless Battery Module (WBM) | Medium5.0 |
| CVE-2022-26390 | Unencrypted internal storage of security credentialsBaxter · Baxter Spectrum Wireless Battery Module (WBM) | Medium4.2 |
| CVE-2022-26392 | Format String vulnerabilityBaxter · Baxter Spectrum Wireless Battery Module (WBM) | Low3.1 |
| CVE-2022-26394 | Unauthenticated network reconfiguration via TCP/UDPBaxter · Baxter Spectrum Wireless Battery Module (WBM) | Medium5.5 |
| CVE-2014-5431 | Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 contains a hard-coded password, which…Baxter · SIGMA Spectrum Infusion System | Medium6.8 |
| CVE-2014-5432 | Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 is remotely accessible via Port 22/SSH…Baxter · SIGMA Spectrum Infusion System | Critical9.8 |
| CVE-2014-5433 | An unauthenticated remote attacker may be able to execute commands to view wireless account credentials that are stored in cleartext on Baxter SIGMA Spectrum…Baxter · SIGMA Spectrum Infusion System | Critical9.8 |
| CVE-2014-5434 | Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 has a default account with hard-coded…Baxter · SIGMA Spectrum Infusion System | Critical9.8 |